60 Simon XT Installation Manual
If the test is unsuccessful, the Status button lights and the display shows Comm
Failure within 10 minutes.
If the test is unsuccessful:
1. Check that the panel is connected to the phone jack.
2. Check the phone number programmed into the panel.
3. Perform the communication test again.
4. If the communication test fails again, check the phone connection wiring.
Offsite phone operation
Test the system from a remote phone by calling the panel and using the
commands in Table 30 below.
Table 30: Phone commands
System function
Phone command
Disarm
1
Arm doors/windows
2
Arm motion sensors
3
Arm doors/windows with no entry delay
2 2
Arm motion sensors with latchkey
3 3
Arm doors/windows and motion sensors
2 3
Arm doors/windows with no entry delay and
motion sensors with latchkey
2 2 3 3
Specific light on
*, <unit number>
Specific light off
#, <unit number>
All lights on
* *
All lights off
# #
System status
0
Audio verification
5 plus X (X= a command from Audio
Verification Set)
Terminate session
9
Central station communication
After performing sensor and communication tests, check that the system is
reporting alarms successfully to the central station. Table 31 on page 61 provides
a list of sensor/user report codes.