Simon XT Installation Manual 45
Nonalarms include: Latchkey, No Activity, Openings, Closings, Fail-to-Open, Fail-
to-Close, Force Armed, AC Power Failure, CPU Low Battery, and Trouble
Restoral.
Timers
Table 18 below describes the Timers menu.
Table 18: Timers menu
Function
Default
Description
Latchkey time
Off
Determines whether the panel reports a latchkey alarm if
the system is not disarmed at a preset time between
midnight and 11:59 p.m. (on). If the latchkey feature is
disabled (off), the panel will not report a latchkey alarm. The
system clock must be set for the latchkey feature to work.
Entry delay
030 seconds
Determines how much time you have to disarm the system
after entering the armed premises through a designated
delay door, before an alarm occurs. Beeps sound during the
entire delay time to remind you to disarm the system. When
turned on, the entry delay can be set from 030 to 240
seconds.
Exit delay
060 seconds
Determines how much time you have to leave the premises
through a designated delay door after arming the system.
Beeps sound after arming the system to remind you to
leave the armed premises. If a delay door is opened after
the exit delay expires, the entry delay begins. If you arm the
system with no delay and open a delay door after the exit
delay expires, an alarm occurs.
No activity tm
Off
Determines whether the panel sends a no activity report to
a central station when the programmed time elapses (on),
or if the feature is disabled (off). No activity means the
control panel, remote handheld, and key-chain touchpad
buttons have not been pressed and sensors have not been
tripped within a specified time (except sensors in group 25).
The timeout can be set from 02 to 24 hours.
Auto phone test
Off
Determines whether the panel automatically performs a
periodic phone test (on), or not (off). The test interval can be
from 001 to 254 days. The time of day the panel performs
the test is determined by the supervisory time, which must
be turned on for this feature to work.
Supervisory time
12:00am
Determines when the panel reports supervisory conditions
(sensor failures) and automatic phone tests to the central
station. The panel clock must be set to the correct time for
this option and the automatic phone test to work correctly.